Mezzanine sub-product · 03 of 03

Decking + flooring.

B-deck + concrete, resin board, bar grating, or diamond plate. The right deck depends on your live load, your fire rating, and what's happening above and below it. 416 spec's it per use, not per catalog.

What it is

Pick the deck that matches the use.

The mezzanine deck does three things at once: carries the live load, defines the fire rating between levels, and decides whether sprinkler water can pass through to the floor below. Wrong deck = code violation, sprinkler shadow, or under-spec capacity.

416 picks the deck per use. Storage at 250 psf with sprinkler coverage above + below gets one answer. An open office floor with low live load gets another. A maintenance platform with chemical exposure gets a third.

Every deck choice is reflected on the P.Eng-sealed drawing — load capacity, deflection limit, fire rating, finish.

  • B-Deck + ConcreteMost common storage deck. 22ga or 20ga B-deck + 2-3" concrete topping. 250+ psf live load. Sprinkler water doesn't pass through.
  • Resin BoardEngineered wood + resin top. Dry, level, quiet. Best for light pick or office above storage. 125 psf typical.
  • Bar GratingOpen serrated steel. Lets sprinkler water + light pass. Required for cold-storage + some hazardous-area mezzanines.
  • Diamond PlateSolid steel deck for heavy maintenance + equipment platforms. Slip-resistant. Easy wash-down.
  • Fire-rated assemblies1-hr + 2-hr assemblies available per OBC where required by occupancy or fire-separation rules.
Deck choices

Four standard finishes.

01 · B-Deck + Concrete

Storage mezzanine standard

22-20ga B-deck with 2-3" concrete topping. 250 psf+. Hard-wearing, fire-resistant. Most common storage choice.

02 · Resin Board

Office + light pick

Engineered wood + resin. Quiet, level, dry. Painted or sealed. 125 psf typical for offices + pick mezzanines.

03 · Bar Grating

Sprinkler + light pass-through

Serrated steel grate. Lets sprinkler water reach below. Required for some cold-storage + hazardous occupancies.

04 · Diamond Plate

Maintenance + equipment platforms

Solid steel raised-pattern deck. Slip-resistant. Best for mechanical decks, chemical exposure, frequent wash-down.

416 standards

Load + fire + sprinkler, checked.

Load

Live load checked + stamped

Every deck assembly is checked against expected live load + impact factor. Deflection limit L/360 per OBC for office, L/240 for storage. Recorded on the drawing.

Fire

OBC fire-rating compliant

Where occupancy or building separations require a rated floor, the deck assembly is spec'd to ULC certification. Documentation included in the submittal.

Sprinkler

Sprinkler coverage verified

If your sprinkler system covers below the mezzanine, the deck choice has to let water through (grate) — or coverage above + below must be added. 416 coordinates with your sprinkler trade.

Install

Tight, plumb, level

All deck panels mechanically fastened to the mezzanine frame. Edges sealed. Level checked corner-to-corner before turnover.

Spec'ing a mezzanine deck?

Send your intended live load + sprinkler context + fire-rating constraint. We'll match the deck on the drawing.